Sekee FM Mechanical Flowmeters
Catalog Navigation
- 1
- visitors are viewing this page
| Characteristic | Value |
|---|---|
| Nominal size, mm | 5, 10, 16, 20, 26 |
| Measured medium temperature, °C | from -40°C to +150°C |
| 1-Wire sensor temperature range, °C | from -55°C to +125°C |
| Ambient temperature, °C | from -55°C to +85°C |
| Maximum operating pressure, MPa | 2,6 |
| Supply voltage, V | 8 – 40 |
| Inrush current Imax, mA | 50 |
| Ingress protection rating | IP 68 |
| Measurement error, % | ±0,5 |
| Verification interval, years | 2 |
| Warranty period, years | 3 |
Mechanical flow meters can be used in liquid flow control systems across various industrial sectors, stationary process installations, ground-based mobile refueling and pumping units, and commercial metering systems on river, sea, rail, road transport, and special equipment.
The operating principle of the meters is based on the passage of liquid entering the measuring chamber through the inlet port. The liquid exerts pressure on the walls of the annular piston, and due to the pressure differential between the chamber inlet and outlet, it creates a force that moves the piston. As the piston moves through the chamber, each cycle displaces a specific volume of liquid. Each piston movement generates an electronic pulse on the electronic reader (Hall effect sensor), which has a corresponding conversion factor for the measured volume.
Mechanical flow meters Sekee FM are available in the following variants depending on the nominal bore diameter: Sekee FM5, Sekee FM10, Sekee FM16, Sekee FM20, Sekee FM26.
| Nominal size, mm | Consumption, kg/h | ||
|---|---|---|---|
| Q min | Q nom | Q max | |
| 5 | 2,5 | 50 | 100 |
| 10 | 2,5 | 180 | 250 |
| 16 | 8 | 400 | 700 |
| 20 | 16 | 1100 | 1600 |
| 26 | 25 | 2000 | 3100 |
Mechanical flow meters can be used in liquid flow control systems across various industrial sectors, stationary process installations, ground-based mobile refueling and pumping units, and commercial metering systems on river, sea, rail, road transport, and special equipment.
The operating principle of the meters is based on the passage of liquid entering the measuring chamber through the inlet port. The liquid exerts pressure on the walls of the annular piston, and due to the pressure differential between the chamber inlet and outlet, it creates a force that moves the piston. As the piston moves through the chamber, each cycle displaces a specific volume of liquid. Each piston movement generates an electronic pulse on the electronic reader (Hall effect sensor), which has a corresponding conversion factor for the measured volume.
Mechanical flow meters Sekee FM are available in the following variants depending on the nominal bore diameter: Sekee FM5, Sekee FM10, Sekee FM16, Sekee FM20, Sekee FM26.
| Characteristic | Value |
|---|---|
| Nominal size, mm | 5, 10, 16, 20, 26 |
| Measured medium temperature, °C | from -40°C to +150°C |
| 1-Wire sensor temperature range, °C | from -55°C to +125°C |
| Ambient temperature, °C | from -55°C to +85°C |
| Maximum operating pressure, MPa | 2,6 |
| Supply voltage, V | 8 – 40 |
| Inrush current Imax, mA | 50 |
| Ingress protection rating | IP 68 |
| Measurement error, % | ±0,5 |
| Verification interval, years | 2 |
| Warranty period, years | 3 |
| Nominal size, mm | Consumption, kg/h | ||
|---|---|---|---|
| Q min | Q nom | Q max | |
| 5 | 2,5 | 50 | 100 |
| 10 | 2,5 | 180 | 250 |
| 16 | 8 | 400 | 700 |
| 20 | 16 | 1100 | 1600 |
| 26 | 25 | 2000 | 3100 |